King Fabrication
King Fabrication · Commercial Kitchen Exhaust

Commercial Kitchen Exhaust Systems, Engineered for Sydney.

AS/NZS-compliant canopies, ducting and make-up air systems. Site survey within 48 hours, fabrication in our own Sydney workshop, fitted by our crew — not subcontracted.

AS/NZS 1668 & 5601 compliant
316 / 304 stainless fabrication
In-house fabrication + install
Sydney sheet metal since 2010
Call 0405 106 128 5.0★ Rated on Google

Get a Kitchen Exhaust Quote

Quotes ready in 2 business days. Site survey within 48 hours of contact.

No spam. We only contact you about this request.

Why King Fabrication

Built right. Installed right. Compliant right.

AS/NZS Compliant

Every system designed and installed against AS 1668.2, AS 5601 and the NCC, so it holds up when the certifier and the council inspector arrive.

In-House Fabrication

No third-party shops. Your canopies and ducting are cut, folded and welded in our Smeaton Grange workshop. Faster lead times, tighter QA.

Sydney Install Crew

Our own install team — no subbies. One point of contact from survey to commissioning.

Built to Last

304/316 stainless construction, fully-welded grease seams, access panels where the cleaners actually need them.

Before you get quotes

What a compliant kitchen exhaust system actually involves.

It is four systems, not one

Most operators ring around for "a canopy". A commercial kitchen exhaust system is really four connected pieces, and a quote that only prices one of them is not comparable to a quote that prices all four.

  • The canopy — the hood itself, with baffle-type grease filters and a drained grease gutter.
  • The exhaust duct — the run from canopy to discharge, sealed and fully welded where it carries grease-laden vapour.
  • The fan and discharge — sized to the canopy load and terminated so it does not dump back into a neighbour's window or an intake.
  • Make-up air — replacement air brought back into the kitchen to match what you are throwing out.

Leave make-up air out and the kitchen goes negative. Doors get heavy, gas appliances struggle to draw, the canopy stops capturing properly, and the air conditioning in the dining room fights the kitchen all night. It is the single most common thing we find missing on systems we are asked to fix.

Why canopy sizing is not just kitchen size

Extraction rate is driven by what sits under the hood, not by the floor area of the room. A char grill and a six-burner range with the same footprint have very different thermal plumes, and the canopy has to be sized to the heaviest appliance in the line-up.

Overhang matters as much as airflow. A canopy that stops short at the front edge of the cooking surface will let plume escape no matter how hard the fan pulls, which is why oversizing the fan is rarely the fix for a hood that smokes into the room.

This is why we survey on site rather than quote off a floor plan. We need to see the appliance line-up, the ceiling height, where the duct can physically run, and where the discharge can legally terminate.

What drives the price

Two kitchens of the same size can differ by a lot, and it is almost always the duct run and the discharge that separate them. A ground-floor kitchen with a short run to an external wall is straightforward. A tenancy four floors up in a mixed-use building, with a riser to negotiate and a residential neighbour above the discharge, is a different job.

  • Duct length, number of bends, and whether the route is accessible or needs ceilings opened up.
  • Stainless grade and gauge — 304 is standard, 316 where there is heavy salt or chemical exposure.
  • Discharge location and any acoustic treatment the council or the building requires.
  • Whether make-up air is ducted in or an existing system can be rebalanced.
  • Out-of-hours work if the venue cannot close.

Building it so it can be cleaned

Grease-laden ductwork has to be cleanable along its whole length, and a system that cannot be cleaned properly becomes both a fire risk and an insurance problem. Access panels have to land where a cleaner can actually reach them, not where they were easiest to fit on installation day.

We place access panels against the cleaning route, fall the ductwork back to the canopy so grease drains rather than pools in low spots, and fully weld the grease-bearing seams instead of relying on sealant that will not survive repeated hot cleaning.

We also clean, service and repair existing systems — including fan replacement, duct cleaning and retrofitting access panels to systems that never had enough of them.

Specification

What we build to.

Standards
AS 1668.2 mechanical ventilation, AS 1668.1 fire, AS 5601 gas installations, and the National Construction Code.
Canopy material
304 stainless as standard; 316 where salt air or heavy chemical exposure applies.
Filtration
Baffle-type grease filters, removable by hand for cleaning, over a drained grease gutter.
Grease ductwork
Fully welded and sealed on grease-bearing runs, falling back to the canopy, with access panels on the cleaning route.
Make-up air
Sized against the exhaust rate so the kitchen does not run negative.
Discharge
Terminated clear of intakes, openable windows and neighbouring tenancies, with acoustic treatment where required.
Install
Our own Sydney crew. Out-of-hours and staged installs available for trading venues.
Site survey
Within 48 hours of contact. Detailed quote within 2 business days of the survey.
How it runs

From first call to a system that passes.

1

Site survey, within 48 hours

We come to you, measure the appliance line-up, work out where the duct can run and where it can legally discharge, and flag anything likely to cause a problem at inspection.

2

Detailed quote in 2 business days

Itemised — canopy, ductwork, fan, make-up air, install. You can see what each part costs instead of getting one number for the lot.

3

Shop drawings

For fit-outs, we supply drawings your builder, certifier or architect can work to before anything is cut.

4

Fabrication in our workshop

Cut, folded and welded at Smeaton Grange. Nothing goes to a third-party shop, so if something needs adjusting we adjust it ourselves.

5

Install and commission

Our crew fits it, balances the airflow, and hands over a system that has been measured rather than assumed.

Reviews

What Sydney operators say about working with Mina and the team.

5.0 out of 5 from 5 Google reviews.

Mina and the boys have been a pleasure to work with. They've helped us install a new extraction system for our printers and their commitment to getting the job right and persevering through challenges is outstanding. 100% recommend.

James PetersenGoogle review

Mina and the team did a great job. Super happy with their services!

Steven NakhlaGoogle review

Mina's team is amazing best service I had

MaryaGoogle review

They do very good and reliable jobs

puujee pjGoogle review
FAQ

Common questions

How fast can you get on site?

Site survey usually within 48 hours of you reaching out. Detailed quote within 2 business days of the survey.

Will it pass council inspection?

We design and install to AS 1668.2, AS 5601 and the NCC, and we flag anything at survey stage that is likely to be queried — discharge location is the usual one. We can supply documentation for your certifier.

Can you work with our existing builder or architect?

Yes, regularly. We can supply shop drawings ahead of fabrication if your team needs them for sign-off, and we are used to working around other trades on a fit-out programme.

What is the typical lead time?

From quote acceptance to commissioned system: 4–8 weeks depending on complexity and how much of the duct route is accessible. A standalone canopy swap can be much faster.

Do you service and repair existing systems too?

Yes — cleaning, repair and servicing of existing exhaust systems, including fan replacement, duct cleaning, and retrofitting access panels where the original install did not leave enough.

Can you install without closing the kitchen?

Usually. Most installs can be staged or run out-of-hours so the venue keeps trading. Tell us your service times at survey and we will scope around them.

Why is my current canopy smoking into the kitchen?

Most often it is make-up air, not the fan. If the kitchen is running negative, or the canopy does not overhang the cooking surface far enough, more extraction will not fix it. We can assess an existing system and tell you which it is.

Get your kitchen exhaust quote.

Two business days from site survey to detailed quote. Call us or fill the form — same response either way.

Call 0405 106 128
📞 Call Now Get Quote