King Fabrication
King Fabrication · Commercial Ductwork

Commercial Ductwork & Ventilation — Built Fast, Built Right, Built Compliant.

End-to-end ventilation builds for commercial kitchens, factories, warehouses and workshops. We design, fabricate and install the whole system — and certify it on commissioning.

Full design + build + install
Compliance certs included
Tested + balanced on handover
24-hour quote turnaround
Call 0405 106 128 5.0★ Rated on Google

Get a Ductwork Quote

24-hour quote turnaround. Free on-site scope.

No spam. We only contact you about this request.

Why King Fabrication

One team, one timeline, one certificate.

Design + Build + Install

No three-way blame games. We design the ventilation system, fabricate the ductwork, and install it. One point of accountability.

Compliance Built In

AS 1668.2 (mechanical ventilation), AS 4254 (ductwork), Section J energy compliance. Certificates issued on commissioning.

Tested + Balanced

Every system is air-flow tested and balanced before sign-off. We hand you commissioning data, not just a handshake.

Sydney-Owned Workshop

Custom spiral and rectangular duct fabricated in our Sydney shop — faster than ordering pre-made. Custom shapes welcome.

Getting the spec right

What separates ductwork that works from ductwork that just fits.

Round, rectangular, or both

Most commercial jobs use a mix, and choosing between them is a trade-off between space and performance rather than a matter of preference.

  • Spiral round duct moves air more efficiently for the same cross-section, is inherently stiffer, and leaks less at the seams. It needs more vertical space, which is often what rules it out.
  • Rectangular duct fits ceiling voids and bulkheads that round duct cannot, at the cost of more surface area, more friction and more sealing to get right.
  • Transitions and offsets are where systems quietly lose performance. A badly made transition can undo the gains from good duct on either side of it.

Because we fabricate rather than order in, we can make the transition pieces the job actually needs instead of forcing the route to suit stock fittings. On retrofits into existing buildings, that is usually the difference between a clean install and a compromised one.

Sealing and leakage are the whole ball game

Duct leakage is the most common reason a system moves less air than it was designed to. It shows up as rooms that never reach temperature, extraction that will not pull, and fans running harder and louder than they should to compensate.

Leakage is cumulative and invisible. A run with many poorly sealed joints can lose a substantial share of its airflow before it reaches the outlet, and no amount of fan capacity fixes it economically — you are just paying to push air into a ceiling void for the life of the building.

We seal to the duct class the system is designed for, and we test and balance before handover so you get measured airflow figures rather than an assurance that it should be fine.

Insulation and Section J

Ductwork carrying conditioned air through unconditioned space has to be insulated to meet the energy provisions of the National Construction Code. Getting this wrong is both an energy cost and a certification problem that surfaces late, when it is expensive to fix.

Duct in a hot roof space is the usual trouble spot. It is also where condensation forms if the vapour barrier is not continuous — which shows up months later as stained ceiling tiles that get blamed on the roof.

We specify insulation and vapour barrier as part of the build rather than leaving it to be sorted on site, and we account for it in the space allowance at design stage so the duct still fits once it is lagged.

Retrofits into occupied buildings

Replacing or extending ductwork in a building that is still trading is a different job from a new fit-out, and most of the difficulty is programme rather than fabrication.

  • Survey what is actually there — as-built drawings are frequently wrong, and existing duct is often a different size or route than documented.
  • Work out what can be prefabricated off site so time on site is assembly rather than manufacture.
  • Stage the work so each shift ends with the building back in a usable state.
  • Plan access and protection through occupied areas before the first ceiling tile comes down.

We fabricate to survey measurements taken on site, which is why we scope in person rather than quoting from a drawing set for retrofit work.

Specification

What we fabricate to.

Standards
AS 4254 ductwork, AS 1668.2 mechanical ventilation, and the energy provisions of the National Construction Code.
Duct types
Spiral round, rectangular, flat-oval, and custom transitions, offsets and plenums made to suit the route.
Materials
Galvanised steel as standard; stainless where the process, washdown or environment requires it.
Sealing
Sealed to the duct class the system is designed for, with joints made to hold that class in service.
Insulation
Specified and allowed for at design stage, with a continuous vapour barrier where duct runs through unconditioned space.
Commissioning
Air-flow tested and balanced before sign-off, with commissioning data handed over.
Fabrication
Cut, rolled, folded and welded in our Smeaton Grange workshop — not ordered in.
Quote turnaround
24 hours from on-site scope.
How it runs

How a ductwork build runs.

1

On-site scope

We measure what is actually there, work out the route, and identify the awkward parts before they become variations. Free, and usually within 48 hours.

2

Quote in 24 hours

Itemised by fabrication and install so you can see where the cost sits.

3

Shop drawings

Supplied to your builder, certifier or head contractor in their format, including RFIs and progress claims where the contract needs them.

4

Fabrication

Made to survey dimensions in our own workshop. Custom transitions and shapes are normal work, not an exception.

5

Install, test and balance

Our crew installs, then tests and balances the system and hands over the commissioning data.

Reviews

What customers say on Google.

5.0 out of 5 from 5 Google reviews.

Mina and the boys have been a pleasure to work with. They've helped us install a new extraction system for our printers and their commitment to getting the job right and persevering through challenges is outstanding. 100% recommend.

James PetersenGoogle review

Mina and the team did a great job. Super happy with their services!

Steven NakhlaGoogle review

Good Job Mina.

Osama HamdanGoogle review

They do very good and reliable jobs

puujee pjGoogle review
FAQ

Common questions

Can you handle the design or do I need a separate consultant?

We can handle the design ourselves for most commercial systems. For specialised cleanroom or pharma applications we partner with a mechanical engineer at no extra cost to you.

How fast can you get a system installed?

Standard commercial fitouts: 4–8 weeks from quote acceptance. Urgent works can be expedited — get in touch and we'll tell you straight up.

Do you work with builders and head contractors?

Constantly. We slot into D&C and traditional contracts. We supply shop drawings, RFIs and progress claims to your format.

Can you make custom transitions and non-standard shapes?

Yes — that is the advantage of fabricating rather than ordering in. If the route needs a piece that does not exist as a stock fitting, we make it to the site measurements.

Do you replace ductwork in buildings that are still trading?

Regularly. We prefabricate as much as possible off site and stage the work so the building is usable at the end of each shift. Tell us your operating hours at scope stage.

What happens if there's an issue post-installation?

12-month workmanship warranty on all installs. Ductwork itself carries the manufacturer's material warranty (typically 10+ years).

Are you insured for site work?

Yes. Current insurance certificates are supplied on request before site mobilisation, in whatever format your head contractor or building manager needs.

Ready to scope your ventilation build?

24-hour quote turnaround. Free on-site scope visit.

Call 0405 106 128
📞 Call Now Get Quote